Power cuts can stop your home life fast. Lights go out, appliances stop, and comfort disappears. Choosing the right generator size avoids stress and wasted money.
A 10 kVA generator can run most houses with normal appliances, but the exact answer depends on your total load, especially if you have heavy equipment like air conditioners or electric stoves.
I sell generators for a living, and I often get this exact question from homeowners. kVA ratings can be confusing if you are not in the trade. A 10 kVA unit is strong enough for many homes, but in some cases, it will not be. The key is checking your load. If you add up all the devices you want to run during an outage, you will know for sure. Without this, you might buy too big or too small, wasting money either way.
People often see kVA and assume it is the same as kW. This is not correct for generators.
A 10 kVA generator usually gives about 8 kW of usable power for most household loads, depending on the power factor.
In my work with generators, I always explain the difference. kVA is the apparent power, a mix of actual working power (kW) and reactive power. For most homes with a power factor of 0.8, a 10 kVA generator will provide around 8 kW. This is enough for lights, fridges, fans, small pumps, and even a small air conditioner. But if your home uses several air conditioners, electric ovens, or other high-load devices at the same time, it may overload the unit. You can check the nameplate of your appliances for wattage and add them up. Always add some margin for starting currents.
Generator Size (kVA) | Power Available (kW) at PF 0.8 | Typical Usage |
---|---|---|
5 kVA | 4 kW | Small home or shop |
10 kVA | 8 kW | Normal home load |
15 kVA | 12 kW | Large home or small business |
Knowing the kW available helps you match the generator to your home’s needs more accurately.
Many buyers want exact answers for appliances. The truth is, it depends on your usage during outages.
A 10 kVA generator can run lights, fans, refrigerator, TV, water pump, and one or two small air conditioners together, but avoid starting too many heavy loads at once.

I have seen many homes that run comfortably on 10 kVA. They keep the essentials on and manage the heavy loads. For example, you can run your fridge, lights, TV, Wi-Fi, and even a split AC at the same time. But when you also try to switch on an electric oven or big motor, the generator will strain. The starting current of motors (AC compressors, pumps) is much higher than the running load. This is why I advise my customers to stagger their usage: start the AC, then the fridge, not at the exact same moment. This helps the generator handle the load without tripping.
Appliance | Average Running Load (W) | Starting Load (W) |
---|---|---|
LED light (10 pcs) | 100 | 100 |
Refrigerator | 200 | 600 |
1HP water pump | 750 | 2200 |
Split AC (1.5 ton) | 1500 | 4500 |
Electric oven | 2000 | 2000 |
This table gives you an idea. You can make your own list for your home to check.
Many customers guess and buy. This often leads to trouble later.
To decide if 10 kVA is enough, list your essential appliances, note their load, and check if the total is less than 8 kW including starting surges.
When I prepare quotes, I ask customers to make a list of what they need during an outage. This includes all lights, fans, pumps, and any heavy load. Then I check the nameplates and find the wattage. I also add starting surges because motors take more power at startup. If the total running load plus surge is under 8 kW, then 10 kVA will be fine. If it is close or higher, I advise a bigger unit like 12 kVA or 15 kVA. Planning this way ensures the generator runs at about 70-80% of its rated load, which is best for its life and fuel economy.
Step | Action | Result |
---|---|---|
1 | List appliances to use during outage | See what power you need |
2 | Record running and starting load | Identify peak load |
3 | Compare to 8 kW output | Confirm size needed |
This small effort before buying will save both money and problems later.
A 10 kVA generator can run most average homes if loads are managed. Always calculate your total and allow for surges to avoid overloading the unit.